产品
product
: Home > 产品 > Fiber Optic Cable > 室外光缆


Applications:Reconstruction of old power lines and low voltage level lines. Coastal chemical industrial areas with heavy chemical pollution.Main Features:Can meet high electrical performance requirements and have excellent corrosion resistant performance.Applicable to coastal areas and areas with

Reconstruction of old power lines and low voltage level lines.
Coastal chemical industrial areas with heavy chemical pollution.
| No. | 1 | 2 | 3 | 4 | 5 | 6 |
|---|---|---|---|---|---|---|
| Color | Blue | Orange | Green | Brown | Gray | White |
| No. | 7 | 8 | 9 | 10 | 11 | 12 |
| Color | Red | Black | Yellow | Violet | Pink | Aqua |
| Specification | Fiber Count | Diameter (mm) | Weight (kg/km) | RTS (KN) | Short Circuit (KA²s) |
|---|---|---|---|---|---|
| OPGW-113(87.9;176.9) | 48 | 14.8 | 600 | 87.9 | 176.9 |
| OPGW-70 (81; 41) | 24 | 12 | 500 | 81 | 41 |
| OPGW-66(79;36) | 36 | 11.8 | 484 | 79 | 36 |
| OPGW-77(72;36) | 36 | 12.7 | 503 | 72 | 67 |
| Item | Test Method | Requirements |
|---|---|---|
| Tension | IEC 60794-1-2-E1. Load: cable length ≥10m, linked ≥100m, time: 1min | 40% RTS: no strain (0.01%) or attenuation (0.03dB); 60% RTS: ≤0.25% strain, attenuation ≤0.05dB |
| Crush | IEC 60794-1-2-E3, three-point load, duration: 10min | Attenuation at 1550nm ≤0.05dB/fiber; no damage |
| Water Penetration | IEC 60794-1-2-F5B: 1hr, 0.5m sample, 1m water height | No water leakage |
| Temperature Cycling | IEC 60794-1-2-F1: -40°C to +65°C, 2 cycles, 12h dwell | Attenuation change ≤0.1 dB/km at 1550nm |
All the OPGW cable supplied from yrtfiber will be 100% tested before shipping. There are different general test series to assure the quality of OPGW cable, such as:

Type test: Type testing may be waived upon submission of a certificate for a similar product issued by an internationally recognized independent test organization or laboratory. If required, type tests will be conducted based on an additional procedure agreed upon by both the purchaser and the manufacturer.
Routine test: The optical attenuation coefficient of all production cables is measured according to IEC 60793-1-CIC (back-scattering technique, OTDR). Standard single-mode fibers are tested at 1310 nm and 1550 nm, while non-zero dispersion shifted single-mode (NZDS) fibers are tested at 1550 nm.
Factory test: Factory acceptance testing is performed on two samples per order in the presence of the customer or their representative. The quality characteristics are determined based on relevant standards and mutually agreed quality plans.